ISOMAXX® concrete-concrete
ISOMAXX® concrete-concrete
Thermal insulation connecting elements with an insulation thickness of 120 mm

Product description

H-BAU further developed the tried-and-tested ISOPRO® balcony-insulating elements, and this resulted in ISOMAXX®. The ISOMAXX® connecting elements reliably create the non-positive locking connection between external concrete components and internal components. With an insulation thickness of 120 mm and outstanding insulating properties, the elements are best suited for use in buildings with particularly stringent requirements for heat protection. The elements are approved by the building authorities in accordance with no. Z-15.7-243 and Z-15.7-244, and reliably reduce thermal bridges in accordance with DIN 4108-2 supplementary sheet 2 and EnEV.

Features

  • Outstanding insulating properties
  • Reduces heating costs
  • Prevents thermal bridges and therefore damage
    caused by mould and moisture
  • Reduces the heat flow in the frame to a minimum 

Technical details

  • Approved by the building authorities and
    type-tested in accordance with EC2
  • 20 mm insulating body: Made of NEOPOR® with
    λ = 0.031 W/mK.
  • Reinforcement rods: Made of B500B and B500NR
  • Pressure pads: Made of high-strength special concrete

ISOMAXX® IM

ISOMAXX® IM

Thermally insulated cantilever slab connection with concrete pressure pads for freely projecting balcony slabs. The element transmits negative bending moments and positive shearing forces.

ISOMAXX® IMT

ISOMAXX® IMT

Thermally insulated cantilever slab connection with steel pressure-bearing plane for freely projecting balcony slabs. The element transmits negative bending moments and positive shearing forces.

ISOPRO® IM + IMT corner

ISOPRO® IM + IMT corner

Thermally insulated slab connection for freely projecting external corner balconies. The element transmits negative bending moments and positive shearing forces.

ISOMAXX® IMTQQS

ISOMAXX® IMTQQS

Thermally insulated slab connection for simply supported slabs where forces are transmitted at selected points. The element transmits positive and negative shearing forces.

ISOMAXX® IMQ

ISOMAXX® IMQ

Thermally insulated slab connection for simply supported slabs (e.g. balconies and loggias on supports). The element transmits positive shearing forces.

ISOMAXX® IMTQS

ISOMAXX® IMTQS

Thermally insulated slab connection for simply supported slabs where forces are transmitted at selected points. The element transmits positive shearing forces.

ISOMAXX® IMTQZ

ISOMAXX® IMTQZ

Thermally insulated slab connection for simply supported slabs where forces are transmitted at selected points with no restraints. The element transmits positive shearing forces.

ISOMAXX® IMTQQ

ISOMAXX® IMTQQ

Thermally insulated slab connection for simply supported slabs. The element transmits positive and negative shearing forces.

ISOMAXX® IMTQQS

ISOMAXX® IMTQQS

Thermally insulated slab connection for simply supported slabs where forces are transmitted at selected points. The element transmits positive and negative shearing forces.

ISOMAXX® IMTH

ISOMAXX® IMTH

Thermally insulated slab connection for absorbing horizontal forces at selected points in connection with cantilever slab or shearing force connections.

ISOMAXX® IMTE

ISOMAXX® IMTE

Thermally insulated slab connection for absorbing horizontal forces and moments at selected points in connection with IMT cantilever slab connections.

ISOMAXX® IMTD

ISOMAXX® IMTD

Thermally insulated slab connection for balcony slabs set in ceiling panels. The element transmits positive and negative bending moments and shearing forces.

ISOMAXX® IMTA

ISOMAXX® IMTA

Thermally insulated connection for connecting parapet walls to the horizontal face of floor slabs.

ISOMAXX® IMTF

ISOMAXX® IMTF

Thermally insulated connection for connecting balustrades to the vertical face of floor slabs.

ISOMAXX® IMO

ISOMAXX® IMO

Wärmegedämmter Anschluss zur Verbindung von Stahlbetonkonsolen mit Geschossdecken.

ISOMAXX® IMTS

ISOMAXX® IMTS

Wärmegedämmter Anschluss zur Verbindung von auskragenden Stahlbetonbalken mit Geschossdecken.

ISOMAXX® IMTW

ISOMAXX® IMTW

Thermally insulated connection for connecting shear walls to floor-to-ceiling walls.

Carnerigasse Graz

Over the course of this project, known as C34, a disused art ...

To the article

WIFI St. Pölten

The new technology centre for WIFI and the Lower Austrian ...

To the article

Golden Ribbons Graz

Striking golden waves snake around the unique façade of the ...

To the article

Herrenhausen Castle Hanover

In 1943, during the Second World War, Herrenhausen Castle was ...

To the article

Hall of residence in Munich

In the new student accommodation in Bavaria's state capital, ...

To the article

Stefan-Andres grammar school Schweich

The district grammar school in the German town of Schweich was ...

To the article

"Die Schwinge" housing complex Ingoldstadt

The housing complex in Ingoldstadt, which was completed in spring ...

To the article

MAD Building Oslo

2004 to 2014 saw the development of Norway's largest urban ...

To the article

ISOPRO® concrete-concrete

ISOPRO® concrete-concrete

ISOPRO® thermal insulation connecting elements reliably create the non-positive locking connection between external concrete components and internal components. With an insulation thickness of 80 mm, ISOPRO® solves the problem of thermal weak points ...

ISOPRO® concrete-steel

ISOPRO® concrete-steel

The ISOPRO® thermal insulation elements, types SBM and SBQ, are elements for connecting steel structures to reinforced concrete components. Thanks to the excellent thermal separation of ISOPRO® elements, structural problems at the intersection ...

ISOPRO® concrete-wood

ISOPRO® concrete-wood

The ISOPRO® range is completed by the ISOPRO® thermal insulation elements types HBM and HBQ. They are used to attach freely projecting or supported wooden constructions, and reliably reduce thermal bridges in accordance with DIN 4108-2 and EnEV. ...

ISOMUR® Plus

ISOMUR® Plus

Thermal bridges caused by geometric and material factors represent a typical weak point in the thermal insulation in the wall-to-base area above the basement ceiling. The ISOMUR® Plus wall base element solves the problem of thermal bridges at the ...